In Vivo 3D Muscle Architecture Quantification Based on 3D Freehand Ultrasound and Magnetic Resonance Imaging
Publiceringsår
2023
Upphovspersoner
Wang, Zhongzheng; Destro, Antea; Petersson, Sven; Cenni, Francesco; Wang, Ruoli
Abstrakt
Muscle architecture parameters, such as the fascicle length, pennation angle, and volume, are important muscle morphology characteristics. Accurate in vivo quantification of these parameters allows to detect changes due to pathologies, interventions, and rehabilitation trainings, which ultimately impact on muscles’ force-producing capacity. In this study, we compared three-dimensional (3D) muscle architecture parameters of the tibialis anterior and gastrocnemius medialis, which were quantified by 3D freehand ultrasound (3DfUS) and a magnetic resonance imaging (MRI) technique, diffusion tensor imaging (DTI), respectively. Sixteen able-bodied subjects were recruited where seven of them received both 3DfUS and MRI measurement, while the rest underwent 3DfUS measurements twice. Good to excellent intra-rater reliability and inter-session repeatability were found in 3DfUS measurements (intra-class correlation coefficient > 0.81). Overall, the two imaging modalities yielded consistent measurements of the fascicle length, pennation angle, and volume with mean differences smaller than 2.9 mm, 1.8°, and 5.7 cm3, respectively. The only significant difference was found in the pennation angle of the tibialis anterior, although the discrepancy was small. Our study demonstrated, for the first time, that 3DfUS measurement had high reliability and repeatability for measurement of muscle architecture in vivo and could be regarded as an alternative to MRI for 3D evaluation of muscle morphology.
Visa merOrganisationer och upphovspersoner
Jyväskylä universitet
Cenni Francesco
Publikationstyp
Publikationsform
Artikel
Moderpublikationens typ
Tidning
Artikelstyp
En originalartikel
Målgrupp
VetenskapligKollegialt utvärderad
Kollegialt utvärderadUKM:s publikationstyp
A1 Originalartikel i en vetenskaplig tidskriftPublikationskanalens uppgifter
Journal
Förläggare
Volym
152
Artikelnummer
111567
ISSN
Publikationsforum
Publikationsforumsnivå
2
Öppen tillgång
Öppen tillgänglighet i förläggarens tjänst
Ja
Öppen tillgång till publikationskanalen
Delvis öppen publikationskanal
Parallellsparad
Ja
Övriga uppgifter
Vetenskapsområden
Gymnastik- och idrottsvetenskap
Nyckelord
[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]
Publiceringsland
Förenta staterna (USA)
Förlagets internationalitet
Internationell
Språk
engelska
Internationell sampublikation
Ja
Sampublikation med ett företag
Nej
DOI
10.1016/j.jbiomech.2023.111567
Publikationen ingår i undervisnings- och kulturministeriets datainsamling
Ja