undefined

Portable emissions toxicity system: Evaluating the toxicity of emissions or polluted air by exposure of cell cultures at air-liquid interface in a compact field-deployable setup

Publiceringsår

2025

Upphovspersoner

Vojtisek-Lom, Michal; Dittrich, Lubos; Pechout, Martin; Cervena, Tereza; Vimrova, Anezka; Sikorova, Jitka; Zavodna, Tana; Ondracek, Jakub; Aakko-Saksa, Päivi; Topinka, Jan; Rössner, Pavel

Abstrakt

<p>Exposure of cell cultures at air-liquid interface (ALI), mimicking i.e. human lung surface, is believed to be one of the most realistic means to model toxicity of complex mixtures of pollutants on human health. The complexity of the close cooperation of “emissions source” and toxicology groups and of the instrumentation are among the limiting factors of ALI. In this work, the concepts of ALI exposure and real-world emissions monitoring using portable emissions monitoring systems (PEMS) are combined into a portable emissions or air toxicity system, for field deployment, including operation in moving vehicles. Cell cultures grown on 6 mm inserts are placed in an airtight 17x13x9 cm exposure box, where the sample is symmetrically distributed into 8 wells of a standard Transwell 24-well holder at 25 cm<sup>3</sup>/min/insert. In a 40x35x45 cm inner dimensions incubator, sample and control air are conditioned to 5 % CO<sub>2</sub>, 37 °C and &gt;85 % humidity and drawn through 2–4 exposure boxes. Characterization with silver nanoparticles revealed 50 % particle losses at 15 nm and deposition rate of approximately 1.5 % at both 10 and 21 nm mean diameter. The system has undergone an extensive field validation, including 4 h of exposure and 2 h transport in a vehicle each day for 5 days, 5-day operation outside in vans and tents at −7 to +32 °C, long transport and test on a heavy-duty truck, during which cells were exposed to the diluted exhaust from the truck, this being the first known use of ALI exposure chamber as PEMS. The portable exposure chamber, along with a field-deployable auxiliary mobile base including a small laminar flow box, additional incubator and freezer, can be easily used to study the toxicity of various emissions, effluents and polluted air, aiming for a more relevant toxicity measure than chemical composition alone.</p>
Visa mer

Organisationer och upphovspersoner

Publikationstyp

Publikationsform

Artikel

Moderpublikationens typ

Tidning

Artikelstyp

En originalartikel

Målgrupp

Vetenskaplig

Kollegialt utvärderad

Kollegialt utvärderad

UKM:s publikationstyp

A1 Originalartikel i en vetenskaplig tidskrift

Publikationskanalens uppgifter

Volym

959

Artikelnummer

178010

Publikationsforum

66887

Publikationsforumsnivå

2

Öppen tillgång

Öppen tillgänglighet i förläggarens tjänst

Ja

Öppen tillgång till publikationskanalen

Delvis öppen publikationskanal

Licens för förläggarens version

CC BY

Parallellsparad

Nej

Övriga uppgifter

Vetenskapsområden

Miljöteknik; Miljövetenskap

Nyckelord

[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]

Språk

engelska

Internationell sampublikation

Ja

Sampublikation med ett företag

Nej

DOI

10.1016/j.scitotenv.2024.178010

Publikationen ingår i undervisnings- och kulturministeriets datainsamling

Ja