Total Rotor Runout Dataset

Beskrivning

Total Rotor Runout Dataset Data of tactile multi-probe and eddy current displacement measurement of an electric motor rotor shaft surfaces. Original measurement data related to publication: T. Tiainen, R. Viitala, T.P. Holopainen, B. Hemming, Analysis of total rotor runout components with multi-probe roundness measurement method, Measurement, Volume 179, 2021, 109422, ISSN 0263-2241, https://doi.org/10.1016/j.measurement.2021.109422. (https://www.sciencedirect.com/science/article/pii/S0263224121004115) All data is in raw format in CSV files. The measurements were triggered with a 1024-pulse rotary encoder and contain 5 rounds of data (5120 points). The multi-probe roundness measurement algorithm implementations are available at: https://github.com/tuomastiainen/mpr-tools Multi-probe roundness data, tactile measurement (Figures 6 and 9) Raw data of four-point tactile roundness measurement. DescriptionFile namez offset (mm)Left polished surface four-point tactile measurementroundness/left-polished.csv477Left journal bearing four-point tactile measurementroundness/left-journal-bearing.csv363Left support bearing four-point tactile measurementroundness/left-support-bearing.csv0Right support bearing four-point tactile measurementroundness/right-support-bearing.csv-1320Right journal bearing four-point tactile measurementroundness/right-journal-bearing.csv-1575 Electrical runout data, simultaneous tactile and eddy current probe measurement (Figures 7 and 8) Raw data of electrical roundness measurement, including one file with S1 and eddy data and another file with S1, S2, S3 and S4 tactile multi-probe roundness measurement data (simultaneous measurement, S1 data are equal in both files). DescriptionFile nameLeft polished tactile and eddy current measurementelectrical-runout/left-polished.csvLeft polished four-point tactile measurementelectrical-runout/left-polished-roundness.csv Scaling All tactile probe readings (S1 to S4) will need to be multiplied by 1/409.6 to obtain the values of the probes in micrometers.Eddy current probe data (analog voltage) was calibrated to the simultaneous eddy current probe measurement as described in the publication. The resulting calibration coefficient was 0.002130021300212892. Names of variables VariableDescriptionnIndex number of measurement point (starting from rotary encoder reference pulse)S1Tactile displacement sensor 1S2Tactile displacement sensor 2S3Tactile displacement sensor 3S4Tactile displacement sensor 4eddyEddy current sensor (voltage)   Acknowledgement This dataset was obtained within the 19ENG07 Met4Wind project. This project has received funding from the EMPIR programme co-financed by the Participating States and from the European Union’s Horizon 2020 research and innovation programme. Project title: Metrology for enhanced reliability and efficiency of wind energy systems Funder name: European Commission Funder ID: 10.13039/100014132 Grant number: 19ENG07 Met4Wind Link to project homepage: https://www.ptb.de/empir2020/met4wind/home/ Related objects: https://doi.org/10.1016/j.measurement.2021.109422
Visa mer

Publiceringsår

2021

Typ av data

Upphovspersoner

ABB Oy - Medarbetare

Department of Energy and Mechanical Engineering

Björn Hemming - Upphovsperson

Raine Viitala Orcid -palvelun logo - Upphovsperson

Timo Holopainen - Upphovsperson

Tuomas Tiainen Orcid -palvelun logo - Upphovsperson

VTT Technical Research Centre of Finland Ltd. - Medarbetare

Zenodo - Utgivare

Projekt

Övriga uppgifter

Vetenskapsområden

Maskin- och produktionsteknik

Språk

Öppen tillgång

Öppet

Licens

Creative Commons Attribution 4.0 International (CC BY 4.0)

Nyckelord

Ämnesord

Temporal täckning

undefined