Multivariate analysis on simulated moisture damage emission to indoor air
Publiceringsår
2026
Upphovspersoner
Lappalainen, V.; Sorvari, Jouni; Sohlberg, E.; Pasanen, P.
Abstrakt
<p>Moisture damage in buildings is a significant source of indoor air problems, releasing e.g. volatile organic compounds (VOCs) and microbially produced VOCs (MVOCs), which can cause unpleasant odors and health symptoms. However, interpreting MVOCs as indicators of mold is challenging due to their various sources and limitations in analytical methods. The objective of this study was to identify the most critical factors influencing VOC emissions from moisture-damaged wall structures into the indoor environment via structural air leakages. The research was conducted using the VTT Indoor Air Quality (IAQ) Simulator and analyzed with Principal Component Analysis (PCA). The IAQ simulator was used to investigate the transport of airborne impurities from mold-contaminated wall structures in realistic building conditions and the systematic manipulation of key environmental parameters. The resulting dataset was subjected to multivariate analysis to identify the most influential factors contributing to IAQ degradation in moisture-damaged structures. The key conclusions revealed that material relative humidity was the most significant single factor affecting all VOC concentrations; higher humidity consistently increased emissions. Four specific ketones (2-pentanone, 2-hexanone, 2-heptanone, and 2-octanone) were clearly identified as originating from microbial growth, with their concentrations being significantly higher in the presence of active mold growth. Pressure differentials had only a borderline effect on gypsum board emissions, while the insulation layer showed no significant impact on any of the identified VOC components. These findings underscore the critical role of relative humidity in determining indoor VOC profiles and highlight the value of multivariate methods in assessing mold-related indoor air problems.</p>
Visa merOrganisationer och upphovspersoner
Publikationstyp
Publikationsform
Artikel
Moderpublikationens typ
Tidning
Artikelstyp
En originalartikel
Målgrupp
VetenskapligKollegialt utvärderad
Kollegialt utvärderadUKM:s publikationstyp
A1 Originalartikel i en vetenskaplig tidskriftPublikationskanalens uppgifter
Journal/Serie
Förläggare
Volym
1019
Artikelnummer
181512
ISSN
Publikationsforum
Publikationsforumsnivå
2
Öppen tillgång
Öppen tillgänglighet i förläggarens tjänst
Ja
Öppen tillgång till publikationskanalen
Delvis öppen publikationskanal
Licens för förläggarens version
CC BY
Parallellsparad
Ja
Övriga uppgifter
Vetenskapsområden
Byggnads- och samhällsteknik; Miljövetenskap
Identifierade tema
[object Object]
Förlagets internationalitet
Internationell
Språk
engelska
Internationell sampublikation
Nej
Sampublikation med ett företag
Nej
DOI
10.1016/j.scitotenv.2026.181512
Publikationen ingår i undervisnings- och kulturministeriets datainsamling